Oxygen Sensor/ Oxygen detector
By using world advanced thermal technology, our oxygen sensor(detector) is capable of testing oxygen & measuring temperature at the same time, it is mainly used in smelting and refining furnaces.
Advantage : easy operation, save time & cost.
Parameters:
1. Range of measurement:
Liquid steel temperature : 1450℃~1750℃
Oxygen electric potential : -200~+350mV
Oxygen range : 1~1000ppm
2. Accuracy :
Oxygen Battery 1600℃ : ±2mV([O]>1000ppm)
±1.5ppm([O]>10ppm)
Thermocouple accuracy : ±4℃
3. Respond time:
Oxygen battery : 6~8s
Thermocouple : 2~3s
Total : 10~12s
4.Success rate in :
Converter,Arc furnace : >85%
LRF, RH, DH,Tundish : >90%